“Clean Surfaces. Steady Cooling. Longer Equipment Life.”
Innovacorp is a manufacturer of cooling water treatment chemicals for chillers, heat exchangers and closed loop cooling systems. In a closed loop, the same water recirculates through the system, which means any scale, corrosion or microbial growth stays inside the loop and keeps building up. Scale on heat exchanger tubes reduces cooling efficiency, corrosion weakens metal parts, and biofilm harbours bacteria that can affect product quality in food and pharma applications. Our range covers scale inhibitors, corrosion inhibitors and biocides selected for closed loop systems. Every batch is manufactured at our facility and tested before dispatch.
Chillers and heat exchangers are designed to move heat from one place to another. Anything that deposits on the heat transfer surface — scale, biofilm or corrosion products — acts as insulation and reduces how much heat the system can move. The compressor then has to work harder to achieve the same cooling, which raises energy consumption. In closed loops, the problem is more concentrated than in open systems, because the same water keeps recirculating. Treating the loop correctly is cheaper than cleaning tubes mechanically or replacing them.
Each product in our cooling water treatment range has its own specification. Indicative values from our standard range:
| Parameter | Typical Value |
|---|---|
| Appearance | Clear to pale yellow liquid |
| Type | Scale inhibitor / Corrosion inhibitor / Biocide / pH regulator |
| pH (1% solution) | 4.0 – 9.0 (depends on product) |
| Active Content | 20% – 50% |
| Density | 1.00 – 1.20 g/cc |
| Shelf Life | 12 months from manufacture |
Dosage depends on the loop volume, metal types and water quality. Indicative ranges:
Exact dosage should be confirmed with our technical team based on your loop parameters and water analysis.
Closed loop chemistry changes with make-up water quality, metal types and load pattern. Our technical team works with your maintenance engineer or plant chemist to review water analysis and recommend the right chemical combination and dosage for your system. For large installations, we arrange field trials before finalising the treatment program.
Q. Why is chemical treatment necessary for chiller and heat exchanger systems?
Chillers and heat exchangers lose efficiency when scale deposits on heat transfer surfaces or
corrosion weakens metal parts. Chemical treatment controls these problems so the system keeps working
at design efficiency.
Q. What is the difference between open recirculating and closed loop cooling systems?
Open recirculating systems (like cooling towers) lose water through evaporation and need continuous
make-up water. Closed loop systems (like chillers) recirculate the same water without evaporation.
The chemical treatment program differs for each type.
Q. What is the dosage of chiller water treatment chemicals?
Typical dosage for scale inhibitor is 5 – 20 ppm, and for corrosion inhibitor is 10 – 30 ppm. Call
+91-9312871070 for guidance based on your loop parameters.
Q. Which industries use these cooling water treatment chemicals?
These chemicals are used in sugar refineries, power plants, HVAC systems, steel plants and chemical
manufacturing units where chillers or heat exchangers are part of the process.